SC Labs’ Colorado laboratory, formerly Agricor Labs, is an ISO 17025 accredited facility that specializes in accurate cannabis testing in a MED licensed facility.
The SC Labs difference
Consistently Accurate Data
Since 2016, our Colorado facility has provided valuable data insights. With pharma-level quality practices, we enable you to make confident business decisions.
Expert Tech Team
From METRC to formulation guidance, lean on our staff to guide you through the ever-changing cannabis landscape.
Terpenoid Data Innovation
Now available! Chemometric reporting of terpenes can differentiate between good products and great ones, helping your brand stand out from the competition.
Improved Data Access
Now available! The Client Service Portal provides convenient access to lab results, catalog views, and QR codes for your customers…all with quick access to support.
SC Labs Client Service Portal now available in Colorado!
Compliance Testing
Product Type | Potency | Pesticides | Mycotoxins | Residual Solvents | Elemental Impurities | Microbiological Contaminants | Homogeneity | Water Activity |
---|---|---|---|---|---|---|---|---|
Flower/Shake/Trim | ✔ | ✔ | ✔ | ✔ | ✔ | |||
Pre-Rolls | ✔ | ✔ | ✔ | ✔ | ✔ | |||
Physical Separation-based Concentrates | ✔ | ✔ | ✔ | ✔ | ||||
Solvent-based Concentrates | ✔ | ✔ | ✔ * | ✔ | ✔ | ✔ ** | ||
Heat/Pressure-based Concentrates | ✔ | ✔ | ✔ | ✔ | ||||
Food-based Concentrates | ✔ | ✔ | ✔ | ✔ | ||||
Marijuana Product | ✔ | ✔ | ✔ | ✔ | ||||
Audited Products | ✔ | ✔ | ✔ *** | ✔ | ||||
Pressurized Metered Dose Inhalers | ✔ | ✔ If made with solvent-based concentrate | ✔ | ✔ | ||||
Vaporizer Delivery Devices | ✔ | ✔ If made with solvent-based concentrate | ✔ | ✔ | ||||
Industrial Hemp Products | ✔ | ✔ | ✔ | ✔ | ✔ |
* Mycotoxins are required on solvent-based concentrates made from flower or trim that failed microbial testing; concentrates made from wet whole plants that were not tested for microbials; or flower, shake or trim that has undergone decontamination.
** Microbiological Contaminants are required on solvent-based concentrates that were produced through Remediation or from Regulated Marijuana wet whole plant that was not tested for microbials
*** Audited products require Total Aerobic Plate Count, Staphylococcus aureus, Pseudomonas aeruginosa, Bile tolerant gram-negative bacteria, and Candida albicans.
Cannabis Flower Batch Sizes
The weight of your harvest batch will determine the number of sample increments and the size of your test package. A harvest batch includes regulated cannabis flower, shake, kief, and trim.
Harvest Batch Size (lbs) | Harvest Batch Size (g) | Number of Sample Increments (0.5 g each) | Min Sample Size (g) |
---|---|---|---|
0.000 - 0.999 | 0.0 - 453.5 | 5 | 2.5 g* |
1.00 - 9.999 | 453.6 - 4535.9 | 8 | 4.0 g* |
10.000 - 19.999 | 4536.0 - 9071.8 | 15 | 7.5 g |
20.000 - 39.999 | 9071.9 - 18143.6 | 22 | 11.0 g |
40.000 - 99.999 | 18143.7 - 45359.2 | 33 | 16.5 g |
100.000 - 199.999 | 45359.3 - 90718.4 | 43 | 21.5 g |
200.000 - 499.999 | 90718.5 - 226796.1 | 53 | 26.5 g |
500 or more | 226796.2 or more | 80 | 40.0 g |
* Microbial testing requires at least 3 grams.
We require at least 8 grams of plant material to perform a full panel.
Cannabis Concentrate Batch Sizes
The weight of your Production Batch will determine the number of Sample Increments and the size of your Test Package. A concentrate batch includes solvent-based, heat/pressure-based, and water-based concentrates.
Production Batch Size (lbs) | Production Batch Size (g) | Sample Increment Size (0.25 g each) | Min Sample Size |
---|---|---|---|
0.000 - 0.999 | 0.0 - 453.5 | 5 | 1.25 g* |
1.00 - 1.999 | 453.6 - 907.1 | 8 | 2.00 g* |
2.00 - 4.999 | 907.2 - 2267.9 | 15 | 3.75 g* |
5.000 - 14.999 | 2268.0 - 6803.8 | 22 | 5.50 g* |
15.000 - 49.999 | 6803.9 - 22679.6 | 33 | 8.25 g |
50.000 - 99.999 | 22679.7 - 45359.2 | 43 | 10.75 g |
100.000 - 249.999 | 45359.3 - 113398.0 | 53 | 13.25 g |
250 or more | 113398.1 or more | 80 | 20.0 g |
*Our Colorado microbial contamination tests require a minimum 6g sample in its own container.
EXAMPLE: if a Production Batch of 4,000 Vaporizer Delivery Devices is manufactured, with each Vaporizer Delivery Device containing 500 milligrams of Marijuana Concentrate, the Production Batch would contain 2,000 grams of Marijuana Concentrate, which would require the collection of at least 15 Sample Increments per Test Batch. But in this case, the manufacturer would have to collect 16 Sample Increments for testing (8 vaporizer Delivery Devices in final form).
Cannabis Product Batch Sizes
Sample Increments = 1 Serving
Number of Servings within Production Batch | Sample Increments to be Collected | Test Batch - 5-Serving Unit* | Test Batch - 10-Serving Unit* | Test Batch - 20-Serving Unit* | Test Batch - 100-Serving Unit* |
---|---|---|---|---|---|
0 - 99 | 5 | 2 | 2 | 2 | 2 |
100 - 999 | 8 | 2 | 2 | 2 | 2 |
1,000 - 4,999 | 15 | 3 | 2 | 2 | 2 |
5,000 - 9,999 | 22 | 5 | 3 | 2 | 2 |
10,000 - 49,999 | 33 | 7 | 4 | 2 | 2 |
50,000 - 99,999 | 43 | 9 | 5 | 3 | 3 |
100,000 - 249,999 | 53 | 11 | 6 | 3 | 3 |
250,000 or more | 80 | 16 | 8 | 4 | 4 |
*Other serving amounts per unit are acceptable. These are provided as examples.
EXAMPLE:
If a Production Batch of 4,000 chocolate bars is manufactured, with each bar containing 100 mg THC and 10 servings per bar, the Production Batch would contain 40,000 Sample Increments which would require the collection of at least 33 Sample Increments per Test Batch. But in this case, the manufacturer would have to collect 40 Sample Increments for testing (4 complete chocolate bars in final form).
- Lab minimum sample is 10 grams of viscous extracts, 16 grams of infused product, and 18 grams for vape cartridges.
- Sampling is conducted on products in final retail form.
Vaporizer Delivery Device Batch Sizes
The size of your production batch will determine the number of Vaporizer Delivery Devices that you will need to submit for testing.
Production Batch Size (g) | Sample Increments (0.25g) | Test Batch Size (g) | 250 mg (units) | 500 mg (units) | 1000 mg (units) |
---|---|---|---|---|---|
≤ 453.5 | 5 | 1.25 | 5 | 3 | 2 |
453.6 - 907.1 | 8 | 2.00 | 8 | 4 | 2 |
907.2 - 2267.9 | 15 | 3.75 | 15 | 8 | 4 |
2268 - 6803.8 | 22 | 5.50 | 22 | 11 | 6 |
6803.9 - 22679.6 | 33 | 8.25 | 33 | 17 | 9 |
22679.7 - 45359.2 | 43 | 10.75 | 43 | 22 | 11 |
45359.3 - 113398.0 | 53 | 13.25 | 53 | 27 | 14 |
≥ 113398.1 | 80 | 20.00 | 80 | 40 | 20 |
EXAMPLE:
If a Production Batch of 4,000 Vaporizer Delivery Devices is manufactured, with each Vaporizer Delivery Device containing 500 milligrams of Cannabis Concentrate, the Production Batch would contain 2,000 grams of Cannabis Concentrate, which would require the collection of at least 15 Sample Increments per Test Batch. But in this case, the manufacturer would have to collect 16 Sample Increments for testing (8 vaporizer Delivery Devices in final form).
Cannabis Pre-Roll Batch Sizes
The weight of your harvest batch will determine the number of Pre-Roll Sample Increments and the size of your Test Package.
Minimum Number of Sample Increments Required to be Collected per Test Batch | Number of Pre-Rolls within the Production Batch | Pre-roll ≤0.39g | Pre-roll 0.40-0.50g | Pre-roll 0.51-0.75g | Pre-roll 0.76-1.00g | Pre-roll 1.01-2.00g | Pre-roll 2.01-3.00g | Pre-roll 3.01+ |
---|---|---|---|---|---|---|---|---|
5 | 0 - 99 | 5 | 4 | 3 | 2 | 2 | 2 | 2 |
8 | 100 - 999 | 8 | 5 | 4 | 3 | 2 | 2 | 2 |
15 | 1000 - 4999 | 15 | 10 | 8 | 5 | 4 | 2 | 2 |
22 | 5000 - 9999 | 22 | 14 | 11 | 8 | 6 | 3 | 2 |
33 | 10,000 - 49,999 | 33 | 21 | 17 | 11 | 9 | 5 | 3 |
43 | 50,000 - 99,999 | 43 | 27 | 22 | 15 | 11 | 6 | 4 |
53 | 100,000 - 249,999 | 53 | 34 | 26 | 18 | 14 | 7 | 5 |
80 | ≥ 250,000 | 80 | 50 | 40 | 27 | 20 | 10 | 7 |
*Our Colorado microbial contamination tests require a minimum 3g sample in its own container.
See our sample requirements for R&D testing.
Sample pickup
Samples must be collected from the licensee’s premises by a Designated Test Batch Collector or licensed lab sampler.
We offer fast sample pick-up all across Colorado, with regular service in the Denver metro, front range, Pueblo, and I-70 corridor. Please contact us for pick-ups outside this area. We’re happy to arrange it!
Dropping off samples?
1301 S. Jason Street, Unit K
Denver, CO 80223
P: (866) 435-0709
M-F: 8 a.m. – 5 p.m.
In-House METRC Support
METRC (Marijuana Enforcement Tracking Reporting Compliance) is a web-based, state-mandated software platform. It’s utilized by several states in which we have labs, so we’re not only knowledgeable about the system, but also have direct access if we need to escalate an issue. Have questions about your lab results in METRC? Please contact us, we’re happy to help!